[frs-150] I increased FusionReactor Version 1.0.6: Metrics Settings: History Size: from 100 to 1000 and now I’ve started having server problems!?


I see the following error

Server Error

The server encountered an internal error and was unable to complete your request.

Application server is busy. Either there are too many concurrent requests or the server is still starting up.

The bug is that the configuration of FusionReactor is updated but the active FusionReactor is not updated with the new setting.

Please update your copy of FusionReactor to the latest version. (The latest 1.x version is 1.0.7.) If you cannot upgrade then the workaround to this problem is to set the Metrics History size to 1000, save the configuration and then restart ColdFusion. You will find that the setting has now taken and that the server works correctly.

Issue Details

Type: Technote
Issue Number: FRS-150
Components: FusionReactor Settings
Environment:
Resolution: Fixed
Last Updated: 25/Jun/07 12:15 PM
Affects Version: 1.0
Fixed Version: 1.0
Server:
Platform:
Related Issues: